The BIO-4P-MAX Cabinet Dispenser is a versatile and efficient solution for dispensing multiple products. Designed for durability and ease of use, this dispenser is ideal for commercial and industrial settings. With its advanced design, it ensures precise dilution and consistent performance.
Package Contents
BIO-4P-MAX Proportioner Unit
Wall Bracket
Supply Tubing
Metering Tip Kit
Discharge Tube for Each Eductor
Instruction Sheet
Installation Kit Including:
Screws and Anchors
Washers
Hosebarb "Y"
In-line Check Valves
Weights and Foot Strainers
Product Labels
Hose Hook
Safety Precautions
Wear protective clothing and eyewear when dispensing chemicals or working near equipment.
Always observe chemical handling instructions from the manufacturer.
Keep equipment clean to maintain proper operation.
Attach the unit securely to water tap outlets (25 PSI minimum, 85 PSI maximum; max water temperature: 120°F).
Direct discharge away from yourself and others or into approved containers.
Installation Instructions
Wall Mounting: Find a suitable location near a water source. Use the wall bracket provided to mark and drill holes. Secure the bracket using the screws and anchors.
Attach Cabinet: Place the cabinet onto the bracket, aligning tabs and slots. Secure the bottom of the cabinet with screws.
Connect Supply Tubing: Cut and attach supply tubing to the hose barb on the selector valve. Ensure tubing reaches the bottom of the chemical container.
Install Discharge Tubes: Attach the appropriate discharge tube for the eductor—short for 1GPM and longer for 3.5GPM.
Water Connection: Connect a water supply hose (minimum 3/8” ID) to the inlet swivel. Ensure proper water pressure for operation.
Operation Instructions
Purge System: Turn on the water supply and press buttons briefly to purge air.
Dispense Product: Depress the button to dispense. For continuous flow, use the button lock.
Adjust Dilution: Use the metering tips to achieve the desired water-to-product ratio.
Maintenance Guidelines
Cleaning: Regularly clean components to prevent buildup.
Eductor Maintenance: Soak in a descaling solution if scale forms. Flush thoroughly after cleaning.
Check Valves: Ensure proper orientation (arrow pointing towards the eductor).
Inspect Tubing: Replace any brittle or damaged tubing.
Troubleshooting
Problem Cause Solution No discharge Water supply not open or clogged parts Open supply, clean or replace parts No concentrate draw Scale buildup or air leaks Clean eductor, check tubing connections Excess concentrate draw Metering tip missing Install the correct metering tip Unit does not turn off Dirty valve or stuck button Clean or replace valve/button Specifications
Water Pressure: 25-85 PSI
Water Temperature: Max 120°F
Flow Rates:
1 GPM (Grey Eductor)
3.5 GPM (Yellow Eductor)